Create a Call Control Recorder Group

Create a Call Control Recorder Group to identify gateway IP addresses and Recorders that are associated with the recording of IP calls within the group.

Procedure 

  1. On the Analyzer server, in Recorder Manager, click General Setup > Call Control. The Call Control window appears.

  2. Click Create.

  3. Complete the Recorder Group fields as follows:

    Item

    Description

    Name

    Type a name for the Recorder group.

    Description

    Type a description (optional) of the Recorder group.

    Gateway IPs

    Click Add, and type the IP address of the Gateway whose SCCP, SIP, or Avaya (H.323) traffic you want forwarded to the remote Recorder, as in the following example: 10.3.4.5. Click Add after each entry to create a new line that will accept a new IP address. The Gateway is the endpoint that the Recorder Group will see RTP traffic for.

    To delete Gateway information, select it, then click Delete.

    Recorders

    Click Add, and type the IP address of the Recorder that is to receive that Gateway’s SCCP/SIP/Avaya (H.323) traffic, along with the port number, as in the following example: 10.3.5.62:3030. Click Add after each entry to create a new line that will accept new information.

    The port number must be a numeric value between 1024 and 65355.

    To delete Recorder information, select it, then click Delete.


  4. Click Save

    The Recorder group is added to the Group Name pane on the left.

View Analyzer

Manage Analyzer

Analyzer setup

Configure Call Control

View Call Control information

Edit a Call Control Recorder Group